As one professional
manufacturer of pulse jet baghouse replacements, Shanghai Indro supplies filter bags, cages and pulse jet valves.
Generally, there are
3 kinds of method to cool high temperature gas in pulse jet bag filters as
followings:
Water cooling:
divided into two methods, one method is to spray water directly into the high
temperature flue gas and cool down, which can be used as a special spay cooling
tower, cooling tower cross-section wind speed is usually 2-3.5 M / sec, the
temperature control system can be used to adjust the water quantity to prevent water
mist from entering the pulse bag filter. Another method is to use cooling water
pipe, installed in the pipeline transporting gas, can prevent the water into
the pulse bag type dust remover and the corrosion problem, this method has
strong cooling capacity and small space occupation, there may be water mist
into the pulse jet bag filter, which possible take moisture and corrosion.
Natural cooling:
Lengthen the length
of the pipeline carrying gas, and make the gas cool down by natural convection
and radiation cooling effect between the pipe and the surrounding air. It can
be used as an “s” type for long intervals. This method is simple, cooling is
weak, and the space occupied is larger.
Cold air mixture:
Inhale a certain
amount of air from the surroundings, which is to mix with high temperature flue
gas to reduce the temperature. When catching traps to collect high temperature
flue gas, the ambient air can be inhaled. Although this method is simple, the
volume of filter gas is increased a lot.
Generally, there are
3 kinds of method to cool high temperature gas in pulse jet bag filters: water
cooling, natural cooling, cold air mixture.